SearchFind a store
Free delivery¹ on appliances with code FREESHIP at checkout.
Induction hob with integrated vapour extraction 

KMDA 7876 FL-U MattFinish

and MattFinish with 2 PowerFlex XL cooking areas for recirculation mode


sale price£3,999.00
Free Delivery with code FREESHIP at checkout. Installation and recycling options available at checkout. For installation of built-in appliances please call 0330 160 6630
 
 

Product details

  • Elegant surface for a unique kitchen design –MattFinish
  • The quietest TwoInOne from Miele –Silence motor
  • Flexible installation – Plug&Play or ducted recirculation mode
  • Ample space – 4 large cooking zones incl.2 PowerFlex XL areas
  • Networking with Con@ctivity andMiele@home

Downloads

Operating instructions/Installation instructions
PDF
Downloads
Product sheet
PDF
Downloads
Warranty conditions
PDF
Downloads
dwg
ZIP
Downloads
rfa
ZIP
Downloads
ifc
ZIP
Downloads
rvt
ZIP
Downloads
fbx
ZIP
Downloads
Product fiche
PDF
Downloads

Whether you are looking to replace an appliance or plan a new kitchen – you will find all the relevant installation drawings for your Miele appliance here. Please note that our products should only be installed and maintained by authorised experts. In the event of queries, please ring us for some no-obligation advice!

https://media.miele.com/images/2000020/200002001/20000200166.png
Descriptions
KMDA7676FL, KMDA7876FL - Installation variant 5 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum depth of the cabinet is 935 mm.
Downloads
https://media.miele.com/images/2000020/200002001/20000200175.png
Descriptions
KMDA7676FL, KMDA7876FL - Installation variant 13 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1125 mm.
Downloads
https://media.miele.com/images/2000020/200002000/20000200088.png
Descriptions
KMDA7676FL, KMDA7876FL - Side view flush - Installation drawing
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation.
Downloads
https://media.miele.com/images/2000020/200002000/20000200090.png
Descriptions
KMDA7676FL, KMDA7876FL - Side view lying on top, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm².
Downloads
https://media.miele.com/images/2000020/200002007/20000200740.png
Descriptions
KMDA7676FL/FR, KMDA7876FL/FR, Plug&Play (Installation drawing)
Installation drawings
Downloads
https://media.miele.com/images/2000020/200002001/20000200167.png
Descriptions
KMDA7676FL, KMDA7876FL - Installation variant 6 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-V, 5) DUU 1500, , The minimum depth of the cabinet is 935 mm.
Downloads
https://media.miele.com/images/2000020/200002000/20000200092.png
Descriptions
KMDA7676FL, KMDA7876FL - Side view flush, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the ventilation opening must be at least 425 cm².
Downloads
https://media.miele.com/images/2000020/200002000/20000200091.png
Descriptions
KMDA7676FL, KMDA7876FL - Side view lying on top+X, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is <gt/> 555 mm from the worktop front, the Plug&Play adapter must be extended with a supplementary set from Miele., ②The removable drip tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., , x Dimension by which the worktop depth is greater than 600 mm.
Downloads
https://media.miele.com/images/2000020/200002001/20000200159.png
Descriptions
KMDA7676FL, KMDA7876FL - Installation variant 2 Basis - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90
Downloads
https://media.miele.com/images/2000020/200002001/20000200176.png
Descriptions
KMDA7676FL, KMDA7876FL - Installation variant 14 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 900 mm.
Downloads
https://media.miele.com/images/2000019/200001998/20000199868.png
Descriptions
KMDA7676FL-U, KMDA7876FL-U - surface installation, drilling template, 23,8 cm, Installation drawing
Installation drawings
Downloads
https://media.miele.com/images/2000020/200002000/20000200087.png
Descriptions
KMDA7676FL, KMDA7876FL - Side view lying on top+X - Installation drawing
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ② The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm.
Downloads
https://media.miele.com/images/2000019/200001999/20000199947.png
Descriptions
KMDA7676FL, KMDA7876FL - flush - Installation drawing
1) Front, 2) removable drip tray, 3) cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Step milling natural stone worktop, 6) Wooden strip 12 mm (not included in delivery), 7) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&play operation: ≥10 mm - ≤40 mm
Downloads
https://media.miele.com/images/2000020/200002000/20000200086.png
Descriptions
KMDA7676FL, KMDA7876FL - Side view lying on top - Installation drawing
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation.
Downloads
https://media.miele.com/images/2000019/200001998/20000199869.png
Descriptions
KMDA7676FL-U, KMDA7876FL-U - surface installation, 24,8 cm, drilling template, Installation drawing
Installation drawings
Downloads
https://media.miele.com/images/2000020/200002000/20000200093.png
Descriptions
KMDA7676FL, KMDA7876FL - Side view flush+X, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is <gt/> 555 mm from the worktop front, the Plug&Play adapter must be extended with a supplementary set from Miele., ②The removable drip tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm²., , x Dimension by which the worktop depth is greater than 600 mm.
Downloads
https://media.miele.com/images/2000019/200001998/20000199870.png
Descriptions
KMDA7676FL-U, KMDA7876FL-U - flush installation, drilling template, Installation depth 24,8 cm, Installation drawing
Installation drawings
Downloads
https://media.miele.com/images/2000019/200001999/20000199945.png
Descriptions
KMDA7676FL, KMDA7876FL - Installation drawing
1) Front, 2) Removable drip tray, 3) Cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&Play operation: ≥10 mm - ≤40 mm
Downloads
https://media.miele.com/images/2000020/200002001/20000200160.png
Descriptions
KMDA7676FL, KMDA7876FL -Installation variant 3 Basis - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90
Downloads
https://media.miele.com/images/2000019/200001998/20000199864.png
Descriptions
KMDA7676FL-U BlackPerfection, KMDA7876FL-U - flush installation, drilling template, Installation depth 23,8 cm
Installation drawings
Downloads
https://media.miele.com/images/2000020/200002001/20000200162.png
Descriptions
KMDA7676FL, KMDA7876FL - Installation variant 4 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm.
Downloads
https://media.miele.com/images/2000020/200002007/20000200738.png
Descriptions
KMDA7676FL/FR, KMDA7876FL/FR, Air circulation (Installation drawing)
Installation drawings
Downloads
https://media.miele.com/images/2000020/200002001/20000200158.png
Descriptions
KMDA7676FL, KMDA7876FL - Installation variant 1 Basis -drawing
1) DFK-AK 90, 2) DFK-R 1000
Downloads
  • 1.Free Delivery with code FREESHIP at checkout. Installation and recycling options available at checkout. For installation of built-in appliances please call 0330 160 6630

We reserve the right to make technical changes; we assume no liability for the accuracy of the information provided.