PG 8536 [AD SST] - Washer-disinfector With AD water connection.--Stainless steel
  • With AD water connection.--Stainless steel
 

PG 8536 [AD SST]
Washer-disinfector
With AD water connection.

  • Performance/cycle, such as 7 DIN mesh trays or 2 MIS sets

    Further stacking options

    Alternatively, 48 GYN specula or 2 AN sets can be reprocessed per cycle.
    For laboratory use up to 66 narrow-necked flasks or 96 pipettes can be processed per cycle.
  • Highest level of flexibility - individually programmable controls

    Programmable controls

    The programmable controls give the washer-disinfectors a high level of flexibility. The machines are already equipped with numerous programmes for all kinds of applications ex works. Authorised users can modify these programmes or upload their own programmes.
  • Safety - spray arm monitoring and automatic mobile unit recognition

    For a reliable result

    Outstanding reprocessing results are achieved through the spray arm sensing, which immediately detects irregular spray pressure or any load blockages.
    In combination with automatic mobile unit recognition, the highest level of safety is guaranteed. By using a magnetic strip, the washer-disinfector recognises the different mobile unit types with their specific loads and automatically selects the appropriate reprocessing programme.
  • Perfect drying results - efficient hot air drying

    Efficient drying

    Active hot air drying is the optimum solution for hollow instruments or narrow-lumened laboratory glassware. The upstream H13 HEPA filter ensures optimum particle separation from the drying air. The filter is easily accessible via a side unit.
  • Total security - interface for process documentation

    Process documentation

    Safety through the clear documentation of all the reprocessing steps.
PG8536 [AD SST]

Optional Accessories - PG 8536 [AD SST]

E 367 Mobile unit
E 367Mobile unit

for the optimum loading of intubation material.

E 443 Irrigation sleeves
E 443Irrigation sleeves

for the optimum cleaning of MIS instruments.

A 18 Lid
A 18Lid

For fixing delicate wash items.

ASA 1 Magnetic spray arm
ASA 1Magnetic spray arm

for spray arm monitoring, suitable for O 167, O 173, O 188, O 190.

E 456 Spring stay
E 456Spring stay

for the optimum hold of open MIS instruments.

E 442 Irrigation sleeves
E 442Irrigation sleeves

for the optimum cleaning of MIS instruments.

E 454 Injector nozzle
E 454Injector nozzle

for optimum cleaning of different wash items, such as trocar sleeves.

E 368 Mobile unit
E 368Mobile unit

for the optimum loading of narrow-lumened breathing tubes.

APH 591 Paper roll
APH 591Paper roll

for protocol printer APH 500 PRT100 and APH 510 PRT110.

E 453 Injector nozzle
E 453Injector nozzle

for the optimum cleaning of different wash items.

E 440/3 Mobile unit
E 440/3Mobile unit

for optimum cleaning of micro instruments (eye OP), for 4 OP sets.

APS 101 Sego Segosoft Miele Edition (additional licences)
APS 101 SegoSegosoft Miele Edition (additional licences)

For connection with a second or additional appliance.

A 811 Replacement net
A 811Replacement net

For replacing the net on an A 810

E 452 Injector nozzle
E 452Injector nozzle

for the optimum cleaning of different wash items.

APH 590 Ink cartridge
APH 590Ink cartridge

for PRT 100 report printer.

E 451 Mesh trays
E 451Mesh trays

For optimum accommodation of different instruments.

E 450/1 Mobile unit
E 450/1Mobile unit

for the optimum loading of MIS instruments.

E 373 Insert
E 373Insert

For the optimum loading of ENT instruments.

E 444 Insert
E 444Insert

for the optimum loading of cold-light cables and suction hoses.

E 135/3 Insert
E 135/3Insert

for optimum loading of 19 baby bottles up to 120 ml.

A 811/1 Replacement net
A 811/1Replacement net

For replacing the net on an A 810/1

A 841/2 Injector nozzle
A 841/2Injector nozzle

with plastic supports, nozzle diameter 6 mm, length 210 mm, 10 items 

E 449 Adapter
E 449Adapter

for the connection of female Luer lock connectors.

E 374 Insert
E 374Insert

for optimum loading of ENT instruments such as inhalation connections.

APH 531 Adapter
APH 531Adapter

For connecting the Miele printer cable to the appliance.

E 448 Silicone hose
E 448Silicone hose

for the optimum cleaning of various instruments.

A 843/3 Injector nozzle
A 843/3Injector nozzle

with plastic supports, nozzle diameter 4 mm, length 185 mm, 20 items

E 378 Insert
E 378Insert

For holding different instruments.

A 843/1 Injector nozzle
A 843/1Injector nozzle

with plastic supports, nozzle diameter 4 mm, length 185 mm, 5 items

E 439/3 Mobile unit
E 439/3Mobile unit

for optimum loading of up to 7 mesh trays.

E 136 Insert
E 136Insert

for optimum loading of 56 half petri dishes.

A 840 Injector nozzle
A 840Injector nozzle

with plastic supports, nozzle diameter 6 mm, length 130 mm, 1 item. 

E 379 Insert
E 379Insert

For holding different instruments.

APH 530 Connection cable
APH 530Connection cable

For interruption-free connection to the printer.

APS 102 Sego SegoAssign Plus
APS 102 SegoSegoAssign Plus

To connect the Segosoft with the in-house patient management system.

E 137 Insert
E 137Insert

for optimum loading of 56 half petri dishes.

A 16 Lid
A 16Lid

For fixing delicate wash items.

A 14 Lid
A 14Lid

For fixing delicate wash items.

SD-B Injector nozzle
SD-BInjector nozzle

for butyrometers.

A 841/1 Injector nozzle
A 841/1Injector nozzle

with plastic supports, nozzle diameter 6 mm, length 210 mm, 5 items 

O 167/1 Upper basket
O 167/1Upper basket

for the optimum loading of insoles for theatre shoes.

O 173/1 Upper basket
O 173/1Upper basket

for the optimum loading of theatre shoes.

O 175 Upper basket
O 175Upper basket

for the optimum loading of laboratory glassware.

E 106 Insert
E 106Insert

For the optimum loading of wide neck flasks, measuring cylinders, etc.

A 842/1 Injector nozzle
A 842/1Injector nozzle

with plastic supports, nozzle diameter 4 mm, length 90 mm, 5 items 

A 13 Lid
A 13Lid

For fixing delicate wash items.

O 176 Upper basket
O 176Upper basket

for the optimum loading of instruments for MIS, arthroscopy and urology.

E 461/2 Mobile unit
E 461/2Mobile unit

for the optimum cleaning of breathing tubes.

E 106/1 Insert
E 106/1Insert

For the optimum loading of wide neck flasks, measuring cylinders, etc.

E 464 Holder
E 464Holder

For E 454 injector nozzles Ø 13 x 65 mm.

MC/2 Transfer trolley
MC/2Transfer trolley

height adjustable, for loading & unloading washer-&disinfectors.

A 844 Injector nozzle
A 844Injector nozzle

with plastic supports, nozzle diameter 2.5 mm, length 80 mm, 1 item.

E 466 Injector nozzle
E 466Injector nozzle

for the optimum loading of breathing bags 8 x 333 mm.

E 467 Irrigation sleeves
E 467Irrigation sleeves

For MIS instruments/clip forceps, length 205 mm, Ø 11 mm.

E 364 Insert
E 364Insert

for the optimum loading of 36 wide-necked teats.

ASA 2 Magnetic spray arm
ASA 2Magnetic spray arm

for spray arm monitoring, suitable for O 191, E 327.

ASA 4 Magnetic spray arm
ASA 4Magnetic spray arm

for spray arm monitoring, suitable for E 439, O 176.

E 363 Insert
E 363Insert

For the optimum loading of GYN and ENT instruments.

E 457 Insert
E 457Insert

for the optimum loading of separable MIS instruments.

E 458 Insert
E 458Insert

for the optimum loading of screw-cap teats.

E 362 Blind stopper
E 362Blind stopper

For the sealing of fittings to load carriers.

AUF 1 Holder
AUF 1Holder

for optimum reprocessing of transmission instruments in upper basket O 177/1.

A 842/2 Injector nozzle
A 842/2Injector nozzle

with plastic supports, nozzle diameter 4 mm, length 90 mm, 10 items

E 460 Insert
E 460Insert

for the optimum loading of different MIS instruments.

E 103/1 Insert
E 103/1Insert

For the optimum loading of test tubes up to 12 x 75 mm.

A 845/2 Injector nozzle
A 845/2Injector nozzle

with plastic supports, nozzle diameter 2.5 mm, length 125 mm, 10 items.

E 355 Mobile unit
E 355Mobile unit

for the optimum loading of narrow necked glassware.

A 14/1 Lid
A 14/1Lid

for securing delicate load items.

E 104/1 Insert
E 104/1Insert

For the optimum loading of test tubes up to 12 x 105 mm.

E 105/1 Insert
E 105/1Insert

For the optimum loading of test tubes up to 12 x 165 mm.

E 135/2 Insert
E 135/2Insert

for optimum loading of 19 baby bottles up to 90 ml.

A 810/1 Cover net
A 810/1Cover net

For optimum securing of delicate items.

E 441/1 Insert
E 441/1Insert

for the optimum loading of Micro instruments.

E 135/1 Insert
E 135/1Insert

for optimum loading of 19 baby bottles up to 110 ml.

APH 406 Network cable
APH 406Network cable

for connection to the network, length 3 m (type 6).

A 814/1 Holder
A 814/1Holder

for optimum reprocessing of tips for Air Scaler and Piezo Scaler.

A 837 Irrigation sleeve set
A 837Irrigation sleeve set

For reprocessing lumened instruments used in ENT applications in particular.

A 3 Cover net
A 3Cover net

As cover for wash items in inserts.

A 842 Injector nozzle
A 842Injector nozzle

with plastic supports, nozzle diameter 4 mm, length 90 mm, 1 item 

DOS S 20 Bellows dispenser pump
DOS S 20Bellows dispenser pump

For dispensing liquid acid media.

E 427 Insert
E 427Insert

for the optimum loading of 6 laryngoscopes.

DOS NA 120 Bellows dispenser pump
DOS NA 120Bellows dispenser pump

For dispensing liquid neutral/alkaline media.

ProCare Protein Check Protein check
ProCare Protein CheckProtein check

for proof of and qualitative assessment of possible protein residues.

E 417/1 Insert
E 417/1Insert

For the optimum loading of up to 30 ear and nose specula.

E 416 Insert
E 416Insert

for optimum loading of 6 single and two-piece specula.

E 445 Irrigation sleeve cover
E 445Irrigation sleeve cover

for the optimum securing of instruments in irrigation sleeves.

E 436/3 Mobile unit
E 436/3Mobile unit

for optimum loading of approx. 3 anaesthesia sets.

E 446 Irrigation sleeve cover
E 446Irrigation sleeve cover

for the optimum securing of instruments in irrigation sleeves.

E 447 Adapter
E 447Adapter

for the connection of male Luer lock connectors.

E 430/1 Insert
E 430/1Insert

For optimum accommodation of different instruments.

A 843/2 Injector nozzle
A 843/2Injector nozzle

with plastic supports, nozzle diameter 4 mm, length 185 mm, 10 items

FP 20 Filter plates
FP 20Filter plates

for the reprocessing of contra angles and hand pieces when using AUF 1/AUF 2.

E 149 Insert
E 149Insert

for optimum loading of 80 test tubes, 16 x 105 mm.

FP ED Filter plates
FP EDFilter plates

Suitable for reprocessing, made of stainless steel, for narrow lumen cannula

A 830/1 Insert
A 830/1Insert

ideal holder for separable mouth specula.

E 146 Insert
E 146Insert

For the optimum loading of different instruments.

A 836 Set of injector nozzles 
A 836Set of injector nozzles 

For optimum reprocessing of lumened instruments used in dental applications.

E 428 Mobile unit
E 428Mobile unit

for the optimum loading of instruments used in robot-assisted surgery.

MT Trolleys
MTTrolleys

for loading & unloading washer-&disinfectors.

E 144 Insert
E 144Insert

For the optimum loading of up to 18 beakers.

A 830 Insert
A 830Insert

Ideal holder for separable mouth specula.

APH 407 Network cable
APH 407Network cable

for connection to the network, length 5 m (type 7).

E 406 Mobile unit
E 406Mobile unit

for the optimum loading of up to 116 pipettes.

ProCare Lab 10 MA - 10 l Liquid detergent, mildly alkaline, 10 l
ProCare Lab 10 MA - 10 lLiquid detergent, mildly alkaline, 10 l

for optimum reprocessing of laboratory glassware and utensils.

E 405/1 Mobile unit
E 405/1Mobile unit

for optimum loading of up to 38 pipettes, connection for hot air drying.

A 841/3 Injector nozzle
A 841/3Injector nozzle

with plastic supports, nozzle diameter 6 mm, length 210 mm, 20 items

E 404/1 Mobile unit
E 404/1Mobile unit

for the optimum loading of up to 38 pipettes.

ProCare Lab 10 AP - 5 l Liquid detergent, alkaline, 5 l
ProCare Lab 10 AP - 5 lLiquid detergent, alkaline, 5 l

For optimum reprocessing of laboratory utensils.

E 402 Insert
E 402Insert

for optimum loading of up to 44 watch glasses.

APH 409 Crossover network cable
APH 409Crossover network cable

for direct connection to PC, length 5 m (type 9).

A 2 Cover net
A 2Cover net

For fixing delicate wash items.

ProCare Lab 30 C - 5 l Neutralising agent, acidic, 5 l
ProCare Lab 30 C - 5 lNeutralising agent, acidic, 5 l

For optimum neutralisation with citric acid based neutralising agent.

E 313 Wall fitting
E 313Wall fitting

for the manual production of demineralised water.

E 385 Mobile unit
E 385Mobile unit

for the optimum loading of narrow necked glassware.

APH 500 PRT 100 Report printer
APH 500 PRT 100Report printer

for printing process reports.

E 381 Mobile unit
E 381Mobile unit

for the optimum loading of intubation material.

E 380 Mobile unit
E 380Mobile unit

for the optimum loading of narrow necked glassware.

E 139/1 Insert
E 139/1Insert

For the optimum loading of test tubes up to 12 x 200 mm.

E 414 Mobile unit
E 414Mobile unit

for the optimum loading of narrow necked glassware.

E 143 Insert
E 143Insert

For optimum accommodation of different instruments.

A 845 Injector nozzle
A 845Injector nozzle

with plastic supports, nozzle diameter 2.5 mm, length 125 mm, 1 item.

APH 408 Crossover network cable
APH 408Crossover network cable

for direct connection to PC, length 3 m (type 8).

ProCare Lab 30 P - 5 l Neutralising agent, acidic, 5 l
ProCare Lab 30 P - 5 lNeutralising agent, acidic, 5 l

For optimum neutralisation with phosphoric acid based neutralising agent.

DTD 2 Drip tray 
DTD 2Drip tray 

For the secure placement of media canisters. 

A 845/1 Injector nozzle
A 845/1Injector nozzle

with plastic supports, nozzle diameter 2.5 mm, length 125 mm, 5 items.

ProCare Lab 10 MA - 5 l Liquid detergent, mildly alkaline, 5 l
ProCare Lab 10 MA - 5 lLiquid detergent, mildly alkaline, 5 l

for optimum reprocessing of laboratory glassware and utensils.

E 142 Insert
E 142Insert

For holding different instruments.

A 5 Lid
A 5Lid

For optimum securing of delicate items.

E 408 Mobile unit
E 408Mobile unit

for the optimum loading of up to 96 pipettes.

E 494 Insert
E 494Insert

for the gentle holding of 5 microtiter plates.

A 843 Injector nozzle
A 843Injector nozzle

with plastic supports, nozzle diameter 4 mm, length 185 mm, 1 item

ADS 1 Silicone adaptor
ADS 1Silicone adaptor

For holding transmission instruments when using AUF 1 or AUF 2.

E 492 Insert
E 492Insert

for the optimum loading of kidney trays.

ID 220 Injector nozzle
ID 220Injector nozzle

with plastic supports, Ø 6, length 220 mm.

E 339/1 Insert
E 339/1Insert

for the optimum loading of up to 12 tray dividers and trays.

O 188/2 Upper basket
O 188/2Upper basket

for the optimum loading of different inserts.

E 489 Universal bracket
E 489Universal bracket

for loading diverse wash items such as insoles for theatre shoes.

A 11/2 Insert
A 11/2Insert

For the gentle cleaning of delicate load items by interrupting the water jet.

E 488 Bracket
E 488Bracket

for the optimum loading of respiratory masks.

E 340 Mobile unit
E 340Mobile unit

for the optimum loading of narrow necked glassware.

E 487 Bracket
E 487Bracket

for optimum loading of 4 theatre shoes up to a height of 280 mm.

E 486 Bracket
E 486Bracket

for the optimum loading of basins.

E 350 Mobile unit
E 350Mobile unit

for the optimum loading of narrow necked glassware.

ML/2 Magnetic strip
ML/2Magnetic strip

for automatic recognition of mobile unit/spray arm monitoring

A 844/1 Injector nozzle
A 844/1Injector nozzle

with plastic supports, nozzle diameter 2.5 mm, length 80 mm, 5 items.

ID 160 Injector nozzle
ID 160Injector nozzle

with plastic supports, Ø 4, length 160 mm.

A 840/2 Injector nozzle
A 840/2Injector nozzle

with plastic supports, nozzle diameter 6 mm, length 130 mm, 10 items.

E 485 Bracket
E 485Bracket

for the optimum loading of 3 kidney trays.

E 134 Insert
E 134Insert

for optimum loading of 210 slides.

E 484 Insert
E 484Insert

for holding different utensils

E 130 Insert
E 130Insert

For the optimum of 10 trays.

ADS 2 Silicone adaptor
ADS 2Silicone adaptor

For holding transmission instruments when using AUF 1 or AUF 2.

A 847 Injector nozzle
A 847Injector nozzle

with support, for cleaning Erlenmeyer flasks.

E 479 Holder
E 479Holder

for micro instruments up to 4 mm Ø.

E 129-06 Insert
E 129-06Insert

For the optimum loading of infusion flasks. Total area 84 x 84 mm.

E 478/1 Holder
E 478/1Holder

for the optimum cleaning of 4 narrow-lumined cannulae (Sautter cannulae).

ID 180 Injector nozzle
ID 180Injector nozzle

with plastic supports, Ø 4, length 180 mm.

A 845/3 Injector nozzle
A 845/3Injector nozzle

with plastic supports, nozzle diameter 2.5 mm, length 125 mm, 20 items. 

ADS 3 Silicone adaptor
ADS 3Silicone adaptor

For holding transmission instruments when using AUF 1 or AUF 2.

E 351 Injector nozzle
E 351Injector nozzle

For the optimum cleaning of the wash items. Size 4 x 160 mm.

E 352 Injector nozzle
E 352Injector nozzle

For the optimum cleaning of the wash items.

A 840/1 Injector nozzle
A 840/1Injector nozzle

with plastic supports, nozzle diameter 6 mm, length 130 mm, 5 items.

E 803 Insert
E 803Insert

for the optimum loading of up to 30 ear and nose specula.

E 328 Support rail
E 328Support rail

for the optimum loading of upright instruments.

ID 240 Injector nozzle
ID 240Injector nozzle

with plastic supports, Ø 6, length 240 mm.

A 810 Cover net
A 810Cover net

For optimum securing of delicate items.

A 848 Injector nozzle
A 848Injector nozzle

with support, for cleaning measuring cylinders.

E 329 Mobile unit
E 329Mobile unit

for the optimum loading of narrow necked glassware.

E 801/1 Insert
E 801/1Insert

for the optimum loading of 8 mouthwash glasses.

E 907/1 Mesh trays
E 907/1Mesh trays

for the optimum loading of different small-scale instruments.

E 792 Silicone hose with connection
E 792Silicone hose with connection

for the connection to female Luer lock connectors.

E 331 Mobile unit
E 331Mobile unit

for the optimum loading of butyrometers.

E 791 Connector
E 791Connector

for the optimum connection of female Luer lock/male Luer lock.

ID 140 Injector nozzle
ID 140Injector nozzle

with plastic supports, Ø 4, length 140 mm.

E 790 Connector
E 790Connector

for the optimum connection of female Luer lock/female Luer lock.

O 184 Upper basket
O 184Upper basket

for optimum loading of centrifuge tubes, phials or test tubes, for example.

A 840/3 Injector nozzle
A 840/3Injector nozzle

with plastic supports, nozzle diameter 6 mm, length 130 mm, 20 items.

E 908/1 Insert
E 908/1Insert

For separable MIS instruments/work inserts or fibre optics.

A 844/3 Injector nozzle
A 844/3Injector nozzle

with plastic supports, nozzle diameter 2.5 mm, length 80 mm, 20 items.

ID 110 Injector nozzle
ID 110Injector nozzle

with plastic supports, Ø 3, length 110 mm.

E 336 Irrigation sleeves
E 336Irrigation sleeves

For the optimum loading of pipettes/MIS instruments in injector units.

E 327/1 Mobile unit
E 327/1Mobile unit

 for the optimum loading of 4 DIN mesh trays.

ID 90 Injector nozzle
ID 90Injector nozzle

with plastic supports, Ø 3, length 90 mm.

E 517 Adapter
E 517Adapter

For connecting a female Luer lock adapter.

PG 8597 Aqua-Soft system
PG 8597Aqua-Soft system

Twin-tank water softener for the continuous removal of soft water up to 40 °dH

O 187 Upper basket
O 187Upper basket

for the optimum loading of narrow necked glassware.

A 841 Injector nozzle
A 841Injector nozzle

with plastic supports, nozzle diameter 6 mm, length 210 mm, 1 item

E 337/1 Insert
E 337/1Insert

for the optimum loading of upright instruments.

E 319/4 Surface filter
E 319/4Surface filter

For optimum protection against contamination from labels or glass splinters.

E 499 Rinse fittings
E 499Rinse fittings

for the optimum loading of suction, rinse and Veress cannulae.

A 844/2 Injector nozzle
A 844/2Injector nozzle

with plastic supports, nozzle diameter 2.5 mm, length 80 mm, 10 items. 

E 498 Nozzle
E 498Nozzle

for optimum loading of double and single tube breathing masks. Height 238 mm.

ProCare Lab 11 MA Powder cleaning agent, mildly alkaline, 10 kg
ProCare Lab 11 MAPowder cleaning agent, mildly alkaline, 10 kg

For optimum reprocessing of laboratory utensils.

E 497 Nozzle
E 497Nozzle

for optimum loading of double and single tube breathing masks. Height 195 mm.

E 319/3 Surface filter
E 319/3Surface filter

For optimum protection against contamination from labels or glass splinters.

E 338 Insert
E 338Insert

for the optimum loading of up to 8 half-shell trays.

U 874/1 Lower basket
U 874/1Lower basket

for the optimum loading of different inserts and mesh trays.

E 496 Injector nozzle
E 496Injector nozzle

with retaining clamp for intubation material.

E 353 Clamps
E 353Clamps

Height-adjustable for optimum positioning of laboratory glassware on the nozzle.

U 184/1 Lower basket
U 184/1Lower basket

for the optimum loading of centrifuge tubes, phials and test tubes.

AK 12/1 Insert
AK 12/1Insert

for loading different utensils.

E 477 Holders
E 477Holders

for micro instruments.

E 470 Injector nozzle
E 470Injector nozzle

for use in the mobile injector unit, Ø 2.5 x 90 mm.

E 110 Insert
E 110Insert

for the optimum loading of beakers from 250 to 600 ml.

E 903/1 Module
E 903/1Module

for the optimum loading of TUR sets (transurethral resection).

E 127-06 Insert
E 127-06Insert

For the optimum loading of infusion flasks. Surface area 57 x 57 mm.

U 874/2 Lower basket
U 874/2Lower basket

for standard DIN mesh trays and Miele inserts.

E 126-06 Insert
E 126-06Insert

For the optimum loading of infusion flasks. Surface area 45 x 45 mm.

E 471 Spring clip
E 471Spring clip

for injector jets with a Ø of 2.5 mm.

E 135 Insert
E 135Insert

for optimum loading of 19 baby bottles up to 250 ml.

O 191/2 Upper basket
O 191/2Upper basket

for the optimum loading of mesh trays.

E 472 Spring clip
E 472Spring clip

for injector jets with a Ø of 4 mm.

RK LWMM Conductivity meter
RK LWMMConductivity meter

for retrofitting on PG 8536.

E 905/1 Module
E 905/1Module

for optimum loading of MIS instruments, such as arthroscopy and urology.

E 476 Holder
E 476Holder

for micro instruments with a Ø of 4-8 mm.

E 125-06 Insert
E 125-06Insert

For the optimum loading of infusion flasks. Surface area 125 x 125 mm.

AK 12 Insert
AK 12Insert

for holding different utensils.

A 12/2 Insert
A 12/2Insert

For the gentle cleaning of delicate load items by interrupting the water jet.

E 124-06 Insert
E 124-06Insert

For the optimum loading of infusion flasks. Surface area 100 x 100 mm.

E 906/1 Module
E 906/1Module

for optimum loading of MIS instruments, such as arthroscopy and urology.

E 111 Insert
E 111Insert

For the optimum loading of beakers from 600 to 1,000 ml.

E 475 Holding bar
E 475Holding bar

for stabilising sleeves.

U 167 Lower basket
U 167Lower basket

for the optimum loading of anaesthetic utensils.

E 118 Insert
E 118Insert

for the optimum loading of half petri dishes.

E 473/2 Filter
E 473/2Filter

with lid, suitable for micro components.

U 168/1 Lower basket
U 168/1Lower basket

for the ideal loading of theatre shoes.

E 131/1 Insert
E 131/1Insert

for optimum loading of 5 mesh and kidney trays.

E 474/4 Basic mobile unit
E 474/4Basic mobile unit

for optimum loading of up to 2 MIS sets in a modular system.

E 109 Insert
E 109Insert

for the optimum loading of beakers up to 250 ml.

O 183 Upper basket
O 183Upper basket

for the optimum loading of instruments for MIS, arthroscopy and urology.

E 469 Irrigation sleeves
E 469Irrigation sleeves

for the optimum loading of MIS instruments from urology, L 300 mm, Ø 11 mm.

UTS Utensil box
UTSUtensil box

for the ideal cleaning of small parts.

ID 200 Injector nozzle
ID 200Injector nozzle

with plastic supports, Ø 6, length 200 mm.

E 354 Clamps
E 354Clamps

Height-adjustable for optimum positioning of laboratory glassware on the nozzle.

O 177/1 Upper basket
O 177/1Upper basket

for optimum cleaning with 26 nozzles and holding of various inserts.

E 468 Insert
E 468Insert

for the optimum loading of different utensils.

ProCare Universal 61 Dishwasher salt, 3 x 2 kg
ProCare Universal 61Dishwasher salt, 3 x 2 kg

For optimum regeneration of the integrated softener.

O 190/2 Upper basket
O 190/2Upper basket

for the optimum loading of different inserts.

E 314 Stand fitting
E 314Stand fitting

for the manual production of demineralised water.

U 175/1 Lower basket
U 175/1Lower basket

for the optimum loading of narrow necked glassware.

A 846 Injector nozzle
A 846Injector nozzle

with support, for cleaning laboratory flasks and round flasks.

E 128-06 Insert
E 128-06Insert

For the optimum loading of infusion flasks. Surface area 71 x 71 mm.

O 176/1 Upper basket
O 176/1Upper basket

for the optimum loading of instruments for MIS, arthroscopy and urology.

E 106/2 Insert
E 106/2Insert

For the optimum loading of wide neck flasks, measuring cylinders, etc.

A 842/3 Injector nozzle
A 842/3Injector nozzle

with plastic supports, nozzle diameter 4 mm, length 90 mm, 20 items

A 12/1 Insert
A 12/1Insert

For the gentle cleaning of delicate items by interrupting the spray jet.

A 11/1 Insert
A 11/1Insert

For the gentle cleaning of delicate items by interrupting the spray jet.

Illustration(s) as an example, for information
*SRP - all prices include VAT
**all prices include VAT, plus shipping costs